Bird-technologies 4331 Manual do Utilizador Página 1

Consulte online ou descarregue Manual do Utilizador para Instrumentos de medida Bird-technologies 4331. Bird Technologies 4331 User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 66
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
INSTRUCTION BOOK FOR
RF DIRECTIONAL
THRULINE
®
WATTMETER
MODEL 43
Also Covers Models
4305, 4330, 4431, 4521-27, and 43P
© Copyright 1998 by Bird Electronic Corporation
Instruction Book Part Number 920-43 Revision. C
Thruline® and Termaline® are registered trademarks of
Bird Electronic Corporation
Electronic Corporation
Cleveland (Solon) Ohio USA
Vista de página 0
1 2 3 4 5 6 ... 65 66

Resumo do Conteúdo

Página 1 - Electronic Corporation

INSTRUCTION BOOK FORRF DIRECTIONALTHRULINE®WATTMETERMODEL 43Also Covers Models4305, 4330, 4431, 4521-27, and 43P© Copyright 1998 by Bird Electronic Co

Página 2

PartsChanges To The ManualWe have made every effort to ensure this manual is accurate. If youshould discover any errors or if you have suggestions for

Página 3 - Safety Precautions

Table of ContentsSafety Precautions. . . . . . . . . . . . . . . . . . . . . . . . iWarningStatements. ...iiCaution Statement. . . .

Página 4 - Warning Statements

Connections. . . . . . . . . . . . . . . . . . . . . . . . . . 19Remote Installation. . . . . . . . . . . . . . . . . . . . . . 20Operating Instructio

Página 5 - Caution Statement

Model 4305A Replacement Parts List. . . . . . . . . . . . 45Model 4330 Thruline Wattmeter. . . . . . . . . . . . . . . 45Model 4330/31 Replacement Par

Página 6

Bird Model 43 Wattmeter

Página 7

Chapter 1IntroductionPurpose and FunctionPerformance Characteristics and Capabilities

Página 8

Bird Model 43 Wattmeter

Página 9 - About This Manual

Raised Stop EdgeStop PinFigure 1Stop PinStop PinContactFigure 2Stop pin andcontactIntroduction

Página 10 - Bird Model 43 Wattmeter

SpecificationsImpedance, Nominal (All Models) 50 ohmsInsertion VSWRAll models except 44314431Less than 1.05:1 maximum1.07 (when coupling is less than3

Página 11 - Table of Contents

Accuracy (All Models CW)(Model 43P, Peak Power)± 5% of full scale.± 8% of full scale.Dimensions, NominalModels 43Model 4431Model 4305AModels 4521/22/2

Página 13

1-5/16"(33.3mm)3-3/8"3-5/8"(92.1mm)(85.7mm)6-7/8"(174.6mm)4"(101.6mm)1-3/4"(44.5mm)Female "N" Q.C.Connectors (

Página 14

Chapter 2Theory of OperationTravelling Wave ViewpointsssCoupling Circuit

Página 15 - Introduction

RF Coaxial LineXMTRorLOADLOADorXMTRDirectional CouplingDetector ElementDiodeMeterDC ContactBypassDCConnectorFigure 3ElementSchematicDiagramBird Model

Página 16

Standing Wave Ratio vs Reflected/Forward Power RatioLoad PowerTheory of Operation

Página 17 - Raised Stop Edge

φφρ φφφp andpp=+−=−+LNMOQP11112φφφWhere p VSWRandWWrf==φBird Model 43 Wattmeter

Página 18 - Specifications

φφφφCAUTIONWhen making low reflection readings using a more sensitiveelement, take care to insert the element so that it sensesreflected power only. D

Página 19

1.05 1.10 1.151.201.25 1.30 1.40.02.03.04.05.06.07.08.09.1.2.3.4.5.6.7.8.91.02.0VSWR—rPERCENT REFLECTED POWER—ff=¾ x 100 =——————————— x 100WrWfREFELEC

Página 20 - Model 43 Outline Drawing

34567891020304050607080901004567VSWR—rPERCENT REFLECTED POWER—ff=¾ x 100 =——————————— x 100WrWfREFELECTED POWERFORWARD POWER2112 3 8Figure 5Percent Re

Página 21 - Theory of Operation

Measurement And Monitoring of Transmitter PowerTesting of Lines, Connectors, Filters, Etc.φφφ= = =01800 00125 01% 106... .or close to or to roughly pB

Página 22 - Figure 3

φφφusing the equation: N ,dB=FHGIKJ10 logWWrfTheory of Operation

Página 23 - Load Power

Safety PrecautionsKeep Away From Live CircuitsDo Not Service Or Adjust AloneSafety Earth GroundShock Hazard

Página 24

Frequency ResponseBird Model 43 Wattmeter

Página 25

Impedance Mismatch20 40 60 80 100 2004006008001000Frequency In Megahertz-10 -5 0-10 -5 0-10 -5 0Relative Response DB10 CElement100 CElement500 CElemen

Página 27

Chapter 3InstallationPortabilityConnectionsWARNINGLeaking RF energy is a potential health hazard. Never attemptto connect or disconnect equipment from

Página 28

Remote InstallationBird Model 43 Wattmeter

Página 29

Installation

Página 30 - Frequency Response

2-1/8"1-1/2"PLUG-IN ELEMENTDETERMINES POWER &FREQUENCY RANGE#10-32 x 9/32 DEEP TAPTWO HOLES7/8"J-411P-4015-1/8"3-13/16"17

Página 31 - Impedance Mismatch

Chapter 4Operating InstructionsZero AdjustWARNINGWhen operating this equipment in conjunction with RF power of200 watts or higher, the potential of th

Página 32

GeneralBird Model 43 Wattmeter

Página 33 - Installation

Normal OperationTo Load To TransmitterTo Load To TransmitterForward Power MeasurementReflected Power MeasurementFigure10Direction ofElementOperating I

Página 34 - Remote Installation

ResuscitationSafety SymbolsWarning StatementsBird Model 43 Wattmeter

Página 35

Bird Model 43 Wattmeter

Página 36 - 1/8" Rad or

1015200.51.01.52.02.53.04.05.02530 4050100 150 200300 400500.2.4.6.81.01.21.41.61.82.0468101214161820VSWR=1+Reflected PowerForward PowerReflected Powe

Página 37 - Operating Instructions

10 15200.51.0 1.52.02.53.04.05.02530 4050100 150 200300 400500.01.02.03.04.05.06.07.08.09.1.2.3.4.5.6.7.8.91.03.02.52.01.61.51.41.31.251.201.161.141.1

Página 38

Figure 13Cable Wavelength Matching Graph200 300 400 60004812162028243236700100FREQUENCY (MEGAHERTZ)500CABLELENGTHINCHESINCHES(10)(9)(8)(7)(6)(5)(4)MEG

Página 39 - Normal Operation

Bird Model 43 Wattmeter

Página 40

Chapter 5MaintenanceTroubleshooting

Página 41 - FORWARD POWER - WATTS

CleaningProblem Possible Cause Corrective ActionNo meter indica-tionNo RF power Check RF source“Arrow” on Plug-inelement pointing in wrongdirectionRep

Página 42

ssssPreventive MaintenanceLine Section CareContact AdjustmentMaintenance

Página 43 - Figure 13

Calibration Checks - Thruline Wattmeter vsTermaline WattmetersBird Model 43 Wattmeter

Página 44

Model 43 Replacement Parts ListItem Qty. Description Part Number1 1 Housing Assembly 4210-0182 1 Cover Assembly 4210-005-13 1 Line Section Assembly 42

Página 45 - Maintenance

Caution StatementSafety Statements

Página 46 - Cleaning

*Available “QC” Type ConnectorsConnector Part Number Connector Part NumberN-Female 4240-062 LT-Female 4240-018N-Male 4240-063 LT-Male 4240-012HN-Femal

Página 47

Figure 14Exploded View Of The Model 43Maintenance

Página 48 - Termaline Wattmeters

Model 4431 Thruline WattmeterTheory of OperationBird Model 43 Wattmeter

Página 49

Maximum CounterclockwiseFrequency (MHz) Sensitivity(Fully Clockwise)4 Full TurnsFrom Max.Position7 Full TurnsFrom Max.Position269(Approximate dBattenu

Página 50

OperationMaintenanceBird Model 43 Wattmeter

Página 51 - Exploded View Of The Model 43

+Model 4431 Replacement Parts ListItem Qty. Description PartNumber11Modified housing (instead of 4210-018) 4431-01121Guide plate assembly 4431-00231Mo

Página 52 - Model 4431 Thruline Wattmeter

Series 4520 Thruline WattmetersInstallationBird Model 43 Wattmeter

Página 53 - Model 4431 Coupling Data

Theory of Operation, Operating Instructions and MaintenanceSectionsSeries 4520 Replacement Parts ListItem Qty. Description Part Number1 1 Mounting pan

Página 54 - Operation

Model 4305A Thruline WattmeterItem Qty. Description Part Number412DC connector assemblyModel 4521/23/25Model 4522/26/274230-01051112MicroammeterModel

Página 55 - Item Qty. Description Part

Model 4305A Replacement Parts ListModel 4330 Thruline WattmeterItem Description Part Number1 Housing assembly 4305A0032 Cover assembly 4305A0023 Line

Página 56

ÉÚ ÉBird Model 43 Wattmeter

Página 57 - Sections

Model 4330/31 Replacement Parts ListModel 43P Peak WattmeterItem Description Part Number1Housing assembly 4330-0042Microammeter, 10µA full scale, 3-1/

Página 58

Model 43P SpecificationsOperationPeak Detector ResponseRF Frequency Range 0.450-2700 MHz. depending on element selected.RF Power Rating 100 mW to 10kW

Página 59 - Item Description Part Number

Model 43P Peak CalibrationBird Model 43 Wattmeter

Página 60 - Model 43P Peak Wattmeter

MaintenanceBatteryBattery+R9-Serial No.Figure 15Model 43PMaintenance

Página 61 - Peak Detector Response

Customer ServiceBird Model 43 Wattmeter

Página 63 - Serial No

DECLARATION OF CONFORMITYManufacturer: Bird Electronic Corporation30303 Aurora RoadCleveland, Ohio 44139-2794Product: Thruline RF Directional Wattmete

Página 65

Bird Model 43 Wattmeter

Página 66 - DECLARATION OF CONFORMITY