56
Bird 5011, 5015, 5011-EF and 5015-EF Terminating Sensors
General Corrected terminated average power
Sensor Type Diode based terminated true average
power measurement
Frequency Range
5011
5011-EF
40 MHz to 4 GHz
40 MHz to 12 GHz
RF Power Range 10
mW to 10 mW
(–20 dBm to +10 dBm)
Max Power
(Damage Level)
2 W avg.
125 W peak for 5 s
Peak/Average Ratio 12 dB max
Uncertainty
*
*. 5011: Above 40 °C, when making measurements at
frequencies between 40 and 100 MHz, add 1%. 5011-
EF: Above 40 °C or below 10 °C, add 1%.
± (5% of reading ± 1 W) (95% c.l.)
(excluding mismatch uncertainty)
(with correction factors for -EF)
RF Connector
5011
5011-EF
N Male
Precision N Male
Impedance, Nominal 50 ohms
Input VSWR:
5011
Typical
Maximum
5011-EF
Typical
Maximum
1.03 (36.6 dB return loss)
1.20 (20.8 dB return loss)
1.05 (32.0 dB return loss)
1.25 (19.1 dB return loss)
Power Supply From host instrument via cable
Temp, Operating –10 to +50 °C (14 to 122 °F)
Temp, Storage –40 to +80 °C (–40 to +176 °F)
Mechanical Shock IAW MIL-PRF-28800F class 3
Vibration IAW MIL-PRF-28800F class 3
Humidity, Max 95% (non-condensing)
Altitude, Max 4,500 m (15,000 ft.)
CE CE compliant
ROHSS ROHSS compliant
Dimensions, Nominal 6” long x 1.5” diameter
Weight, Max 0.75 lb. (0.35 kg)
Recommended
Calibration Interval
12 Months